<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-30 20-33-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 73 kHz 14620 15,5130
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 5,05 dBr 6,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 73 kHz MIN: 12 kHz % above 76 kHz: 15,5130 Acquired: 2025/03/30 20.31.57 Total samples: 14620 Equivalent time: 0:12:11 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,8 dBr MIN: 3,0 dBr AVE: 5,05 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2025/03/30 20.31.56) 20.18 20.20 20.22 20.24 20.26 20.28 20.30 0 2 4 6 Pm [dBr]